          【Case Study】LED Dental Curing Light Registration in China

          from CIRS by

          1. Introduction

          Product Name: LED Curing Light, Dental Curing Light

          Product Composition:

          1. Network power supply: main unit, power adapter, light guiding component, shading device, etc.

          2. Internal power supply: main unit, power adapter, battery, light guiding component, charging stand, etc.

          Working Principle: The light-emitting diode is used as a light source to emit a light source of a certain wavelength effective for the dental restoration material, and the light-conducting component collects light and is led out, so that the dental restoration material is rapidly solidified under the action of the radiation energy.

          Typical Structure:

          2. Classification

          Classification Code: 17-03-06 Class II curing equipment

          Product Description: It usually consists of a light source handle and a power supply. By emitting light of a specific wavelength and utilizing the principle of photopolymerization, the photocurable material is rapidly and efficiently polymerized and cured in a short time. The light source has two types: quartz tungsten halogen lamp and LED lamp.

          Expected Usage: Used to cure photocurable materials.

          3. Registration Unit

          Classified by light source:

          1. Light curing device with quartz tungsten halogen lamp as light source

          2. Light curing device with light emitting diode (LED) lamp as light source

          Classified by power supply:

          1.1. Stand-alone device, a light curing unit powered by a power supply network (including the type that can be used with either a network power supply or an internal battery)

          1.2. Accessories, the dental treatment machine is only powered, clinically adjusted by the curing machine itself to the treatment mode and the output of light energy

          1.3. Accessories, which is a built-in module of the dental treatment machine. Powered by the dental unit and adjusted by the control panel of the dental unit to the treatment mode and light energy output of the curing unit

          2. Stand-alone device, light curing unit powered by internal battery (e.g. rechargeable battery)

          Note:Different light source and power supply should be divided to different registration units, but the LED curing light with power supply 1.1 and 1.2 (having charging base)

          4. Technical Requirements

          Performance index (for LED curing device with internal battery):

          1. General requirements: Clause 5.1 of YY 0055.2-2009

          2. Requirements of Radiation:

          Light source

          Light emitting diode (LED) lamp

          Power supply

          Stand-alone device, powered by internal battery

          Working Mode

          Wavelength range (unit: nm)

          Radiation value (unit: mW/cm2)

          Mode 1

          Full wave band

          Required by enterprise

          190385

          Not more than 100

          400515

          Required by enterprise

          515

          Not more than 100

          3. Appearance: The surface of the whole product should be smooth and clean, and there should be no defects such as corrosion spots, dirt and scratches; plastic and rubber products must not have defects such as foaming, cracking, mildew, sharp edges, burrs and deformation.

          4. Light guiding element: including optical effective area and tolerance.

          5. Photobiosafety: the requirements in GB/T 20145-2006.

          6. Safety requirements: the requirements in GB 9706.1-2007 medical electrical equipment Part 1: Safety general requirements.

          7. Electromagnetic compatibility requirements: the requirements in YY 0505-2012.

          8. Environmental test requirements: the requirements of the climatic environment test group II and the mechanical environment group II in GB/T 14710-2009.

          Table 1 Relevant Product Standards

          Standard Number

          Standard Name

          GB 9706.1-2007

          Medical electrical equipment –

          Part 1: General requirements for safety

          YY 0505-2012

          Medical electrical equipment - Part 1-2: Safety general requirements parallel standard: Electromagnetic compatibility

          GB/T 14710-2009

          Medical electrical environment requirements and test methods

          YY/T 0316-2008

          Medical device risk management for medical devices

          GB/T 16886.1-2011

          Biological evaluation of medical devices –

          Part 1: Evaluation and testing in the process of risk management

          YY/T 0268-2008

          Dentistry Oral Medical Device Biology Evaluation

          Unit 1: Evaluation and Trial

          YY 0055.1-2009

          Dental curing light - Part 1: Quartz tungsten halogen lamps

          YY 0055.2-2009

          Dental curing cameras - Part 2: Light-emitting diode (LED) lamps

          GB 9706.15-2008

          Medical electrical equipment - Part 1-1: General safety requirements parallel standard: Medical electrical system safety requirements

          YY 0709-2009

          Medical electrical equipment-Part 1-8: General requirements for safety. Parallel standard: General requirements, testing and guidance for alarm systems in medical electrical equipment and medical electrical systems

          GB 4943.1-2011

          Information technology equipment - Safety –

          Part 1: General requirements

          YY(/T): Industry standard (Recommendation)

          GB(/T): National standard (Recommendation)

          5. Clinical Trials

          Animal Test or Small Sample Test: not required

          Clinical Trials: not required

          In Medical Device Catalog Exempted from Clinical Trials

          The blue light is irradiated by the repairing material to cure the material, and the light curing machine is divided into a quartz tungsten halogen lamp as a light source and an LED light curing device which is a light source (LED) lamp as a light source. Product performance indicators use the applicable parts of the following reference standards, such as: YY 0055 light curing machine series standards.

          6. Registration Cost and Duration

          1) Product Testing

          Test items

          Testing duration(90 working days total)

          Testing fee(USD)

          Safety Performance

          90

          6,000

          EMC

          90

          3,700

          Biocompatibility

          35

          3,000

          Notes:

          1. The price of EMC is only the price of one operating mode. If there are multiple operating modes, it needs to be re-priced;

          2. Biocompatibility is only the price of a single material, such as a variety of materials and human contact, need to accumulate;

          3. Biocompatibility is only the way the material and the human body are in contact with the oral mucosa, short-term contact within 24h

          2) Technology Approval

          60 working days

          Another 60 working days if the 1-year supplement is required

          3) Administrative Approval

          20 working days

          If you would like to get the detailed registration proposal, please contact us via md@cirs-group.com.

            

          We have launched a LinkedIn newsletter to keep you up to date on the latest developments across the chemical industry including food and FCMs and personal and home care.

          Contact Us
          +86 571 8720 6559 (GMT+8 8:30~17:00)
          Contact Us
          +86 571 8720 6559 (GMT+8 8:30~17:00)
          1. <dfn id="8ngdu"></dfn>

            1. <dfn id="8ngdu"></dfn>
              <rp id="8ngdu"><address id="8ngdu"></address></rp>
                <video id="8ngdu"><menu id="8ngdu"><kbd id="8ngdu"></kbd></menu></video>

                1. <b id="8ngdu"></b>

                亚洲国产精品激情在线观看